Inquiry / Contact
igus® Canada

180 Bass Pro Mills Drive

Concord

Ontario L4K 0G9

(800) 965-2496
+1 905 7608688

Special cables

Categories
Filter
Application Requirements
Cable structure
Certifications and approvals

Number of products: 6

chainflex® CFTHERMO thermocouple cable

  • Requirements: For heavy duty applications
  • Outer jacket: PUR
  • Overall shield
  • Coolant resistant
  • Notch-resistant
  • Hydrolysis and microbe-resistant
  • Halogen-free
  • Silicone-free
  • UV-resistant
  • PVC-free
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
from 5.32 USD/ft
Shop now
UV resistance
Medium Silicone-free
Free from silicon which can affect paint adhesion (according to PV 3.10.7 – status 1992). Halogen-free
Following EN 60754 EAC
Certified to no. TC RU C-DE. ME77.B.01254 CTP
Certified to no. C-DE.PB49.B.00416 Lead free
Following 2011/65/EU (RoHS-II) Clean room
According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1 CE
Following 2014/35/EU

chainflex® control cable for rail vehicles CFSPECIAL-414

  • Requirements: For heavy duty applications in rail vehicles
  • Outer jacket: Special mixture
  • Flame retardant
  • Halogen-free
  • UV-resistant
  • PVC-free
  • Oil resistance: Oil-resistant according to DIN EN 60811-2-1
  • Toxicity: Low toxicity according to EN 50305-9.2
  • Smoke gas density: Low smoke gas density according to EN 61034-2
from 4.25 USD/ft
Shop now
UV resistance
High Flame retardant
Flame-retardant (following DIN EN 60332-1-2, DIN EN 45545-2) Fire safety class: 3 (in accordance to EN 45545-2) or 4 (in accordance to DIN 5510-2) Halogen-free
Following EN 50267-2-1 Lead free
Following 2011/65/EU (RoHS-II) CE
Following 2014/35/EU Toxicity
Low toxicity according to EN 50305-9.2 Smoke gas density
Low smoke gas density according to EN 61034-2

chainflex® CFFLAT motor cable

  • Requirements: For heavy duty applications
  • Outer jacket: TPE
  • Bio-oil-resistant
  • Hydrolysis and microbe-resistant
  • Halogen-free
  • Silicone-free
  • PVC-free
  • UV resistance: High
Upon request
Shop now
UV resistance
High Silicone-free
Free from silicon which can affect paint adhesion (according to PV 3.10.7 – status 1992). Halogen-free
Following EN 60754 EAC
Certified according to No. TC RU C-DE.ME77.B.01255 Lead free
Following 2011/65/EU (RoHS-II) Clean room
According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1 CE
Following 2014/35/EU

chainflex® PUR bus cable for hanging CFSPECIAL-182 applications

  • Requirements: For increased tensile load
  • Outer jacket: PUR
  • Overall shield
  • Bio-oil-resistant
  • Coolant resistant
  • Notch-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Flame retardant
  • Hydrolysis and microbe-resistant
  • PVC-free
from 7.12 USD/ft
Shop now
UV resistance
High Offshore
MUD-resistant following NEK 606 - status 2009 Flame retardant
According to IEC 60332-1-2, CEI 20-35, VW-1, FT-1 Silicone-free
Free from silicon which can affect paint adhesion (according to PV 3.10.7 – status 1992). Halogen-free
Following EN 50267-2-1 UL/CSA AWM
Style 10138 and 20233, 300 V, 80 °C NFPA 79
Following NFPA 79-2012 chapter 12.9 Lead free
Following 2011/65/EU (RoHS-II)

chainflex® PUR hybrid cable for axis 7 of CFSPECIAL-792 robots

  • Requirements: Especially for axis 7 on robots
  • Outer jacket: PUR
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Coolant resistant
  • Hydrolysis and microbe-resistant
  • Halogen-free
  • Notch-resistant
  • Flame retardant
from 15.96 USD/ft
Shop now
Offshore
MUD-resistant following NEK 606 - status 2009 Flame retardant
According to IEC 60332-1-2, CEI 20-35, VW-1, FT-1 Silicone-free
Free from silicon which can affect paint adhesion (according to PV 3.10.7 – status 1992). Halogen-free
Following EN 60754 UL/CSA AWM
Style 10258 and 20234, 1000 V, +80 °C<br />CFSPECIAL.792.012: Style 11323 and 21223, 1000 V, 80 °C NFPA 79
Following NFPA 79-2012 chapter 12.9 Lead free
Following 2011/65/EU (RoHS-II) CEI
Following CEI 20-35 CE
Following 2014/35/EU

chainflex® bus cable CFSPECIAL.484

  • Requirements: For heavy duty applications in rail vehicles
  • Outer jacket: Special mixture
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 60811-2-1
  • Flame retardant
  • Smoke gas density: Low smoke gas density according to EN 61034-2
  • Toxicity: Low toxicity according to EN 50305-9.2
  • Self-extinguishing
from 7.21 USD/ft
Shop now
UV resistance
High Flame retardant
Flame-retardant (following DIN EN 60332-1-2, DIN EN 45545-2) Fire safety class: 3 (in accordance to EN 45545-2) or 4 (in accordance to DIN 5510-2) Halogen-free
Following EN 60754 Lead free
Following 2011/65/EU (RoHS-II) CE
Following 2014/35/EU Smoke gas density
Low smoke gas density according to EN 61034-2 Toxicity
Low toxicity according to EN 50305-9.2

Application Assistance

I would be happy to answer your questions personally

Scott Parker

Product Manager e-chains®

Email

Customer Service:

Monday to Friday from 8 am - 5 pm

Online:

24h