My contact person
igus® Canada

180 Bass Pro Mills Drive

Vaughan

Ontario L4K 5W4

+1 905 7608448
+1 905 7608688

Bus cables

The chainflex® bus cables are available for all well-known industrial bus systems such as Profibus, Interbus, Profinet, Ethernet, CAN-Bus, DeviceNet, ASi or CC link. Depending on the cable family, they can be used for torsion, for severe climatic conditions, for narrow radii, or particularly long travel distances, at high speeds and accelerations. Tested in the igus® laboratory with millions of cycles in e-chains®, they provide guaranteed safety against failure.
  • Bending radii up to 7.5xd
  • Jacket materials: PVC, iguPUR, PUR or TPE

Products

Filter

Application Requirements
Cable structure
Material
Certifications and approvals

Number of products: 11

chainflex® bus cable CF888
  • Requirements: For flexing applications 
  • Outer jacket: PVC 
  • Overall shield
  • Oil resistance: No oil resistance 
  • Flame retardant
  • chainflex® class: 3.1.1.1 

Upon request

Shop now
chainflex® bus cable CFBUS-PVC
  • Requirements: For medium duty applications 
  • Outer jacket: PVC 
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 50363-4-1 
  • Flame retardant
  • UV-resistant
  • chainflex® class: 4.3.2.1 

from 1.59 USD / ft

Shop now
chainflex® bus cable CF898
  • Requirements: For flexing applications 
  • Outer jacket: iguPUR 
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2 
  • Flame retardant
  • UV-resistant
  • chainflex® class: 3.1.3.1 

from 1.65 USD / ft

Shop now
chainflex® bus cable CFBUS-PUR
  • Requirements: For medium duty applications 
  • Outer jacket: PUR 
  • Overall shield
  • Coolant resistant
  • Notch-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2 
  • Flame retardant
  • PVC-free
  • Hydrolysis and microbe-resistant
  • UV-resistant
  • Halogen-free
  • chainflex® class: 4.3.3.1 

from 2.12 USD / ft

Shop now
chainflex® bus cable CFBUS
  • Requirements: For extreme heavy duty applications 
  • Outer jacket: TPE 
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA 
  • Flame retardant
  • Hydrolysis and microbe-resistant
  • UV-resistant
  • chainflex® class: 6.6.4.1 

from 2.37 USD / ft

Shop now
chainflex® bus cable CF11-LC
  • Requirements: For extreme heavy duty applications 
  • Outer jacket: TPE 
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA 
  • PVC-free
  • Hydrolysis and microbe-resistant
  • UV-resistant
  • Halogen-free
  • chainflex® class: 6.6.4.1 

from 5.80 USD / ft

Shop now
chainflex® bus cable CF11-LC-D
  • Requirements: For extreme heavy duty applications 
  • Outer jacket: TPE 
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA 
  • UV-resistant
  • Halogen-free
  • chainflex® class: 6.6.4.1 

Upon request

Shop now
chainflex® bus cable CFROBOT8
  • Requirements: For twistable applications 
  • Outer jacket: PUR 
  • Overall shield
  • Coolant resistant
  • Notch-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2 
  • Flame retardant
  • Hydrolysis and microbe-resistant
  • UV-resistant
  • chainflex® class: 6.1.3.3 

from 9.47 USD / ft

Shop now
chainflex® bus cable CFBUS.LB
  • Requirements: For heavy duty applications 
  • Outer jacket: TPE 
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 60811-404, resistant to organic oils according to VDMA 24568 with Plantocut 8 S-MB by DEA 
  • PVC-free
  • UV-resistant
  • Halogen-free
  • chainflex® class: 7.6.4.1 

Upon request

Shop now
chainflex® bus cable CFSPECIAL.484
  • Requirements: For heavy duty applications in rail vehicles 
  • Outer jacket: Special mixture 
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 60811-2-1 
  • Flame retardant
  • Smoke gas density: Low smoke gas density according to EN 61034-2 
  • Toxicity: Low toxicity according to EN 50305-9.2 
  • Self-extinguishing

Upon request

Shop now
chainflex® bus cable CFROBOT8.PLUS
  • Requirements: For twistable applications 
  • Outer jacket: PUR 
  • Overall shield
  • Coolant resistant
  • Notch-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2 
  • Flame retardant
  • Hydrolysis and microbe-resistant
  • UV-resistant
  • chainflex® class: 6.1.3.4 

Upon request

Shop now

Consulting

I would be happy to answer your questions personally

Scott Parker

Product Manager e-chains®

Write e-mail

Shipping and consultation

In person:

Monday to Friday from 7 am - 8 pm

Online:

24h